General Catalogue - Heavy Duty Vitrified Tiles

SPECIFICATION DURATECH 19.0 23.75 • Colours in the catalogue are as accurate as printing process allows. please check actual tile sample before making the nal selections. • Sizes mentioned in the catalogue are nominal sizes only. • No claim will be entertained once the tiles are xed. • For better laying, please follow the instructions on the packaging box. • Please make sure to check the shade/nish with the sales agent/ dealer before making the nal purchase because there might be variation in actual nish that shown in the catalogue. The company will not bear any loss in such case. Dimensions & surface Quality Physical charactersitics Mechanical charactersitics Safety charactersitics Thermo photo charactersitics Chemical characteristics charactersitics ISO 10545:2/IS:13630 (P-1) ISO 10545:2/IS:13630 (P-1) ISO 10545:2/IS:13630 (P-1) ISO 10545:2/IS:13630 (P-1) ISO 10545:2/IS:13630 (P-1) ISO 10545:2/IS:13630 (P-1) Deviation in length and width Deviation in thickness Deviation in Staightness of sides Deviation in Rectangualrity Deviation in Surface Flatness Surface Quality (%) ± 0.6% ± 5% ± 0.5% ± 0.5% ± 0.5% Minimum 95% ± 0.1% ± 5% ± 0.1% ± 0.1% ± 0.5% Minimum 95% ± 0.1% ± 4% ± 0.1% ± 0.1% ± 0.2% No visible defects Scratch Hardness of surface Moh's scale Water absorption Moisture Expansion, in mm/m SurfaceAbrasion Resistance 7. 8 9 10 Required ≤0.5% Nil As per Mfg. Min. 5 0.02, Max Min Class 2 6 <0.1% Nil Min. Class-4 EN-101/IS:13630 (P-13) ISO 10545:3/IS: 13630 (P-2) ISO 10545:10 ISO 10545:7 1300 N 2 >35 N/mm Declared by manufacturer Min 1300 N 0.55, Min >3000N 2 ≥40 N/mm Min. 0.55 ISO 10545:4/IS: 13630 (P-6) ISO 10545:4/IS: 13630 (P-6) ISO 10545:5/IS:13630 (P-14) Required ≥0.4 Min 2.20 gm/cc - 2.30 gm/cc ≥0.5 DIN 51082/IS: 13630 (P-2) ISO 10545:17 Resistant to 10 cycles -6 -1 9×10 K Max Resistant As per Mfg. Min 10 cycles -6 -1 6×10 K Max Required - Pass min 10 cycles -6 -1 <6×10K Max Resistant Min 10 cycles ISO 10545:9/IS: 13630 (P-5) ISO 10545:8/IS:13630 (P-4) ISO 10545:12/IS: 13630 (P-10) ISO 10545:11 Min class-3 Required Min conform to class-4* ISO 10545:14 ISO 10545:13/IS:13630 (P-7) ISO 10545:13/IS:13630 (P-7) ISO 10545:13/IS:13630 (P-7) Conform to classes-UA* Conform to classes-ULA* Conform to classes-UHA* Required Required Required min class-UB min class-ULB min class-UHB 11 12 13 Breaking strength Modulus of rupture Impact resistance 1. 2. 3. 4. 5. 6. 14 15 Density Skid resistance (Friction coeeficient ) 16 17 18 19 20 21 22 23 Thermal shock resistance Co efficient of thermal expansion Frost resistance Crazing Resistance Stain Resistance Chemical Resistance HOUSE HOLD CHEMICAL & SWIMMING POOL SALT Chemical Resistance LOW CONCENTRATIONS ACID & ALKALIES Chemical Resistance Averages 0.08, Individual maximum 0.1% Average 35, Individual minimum 32 PROPERTY S.No. GROUP BIA - ISO 13006/EN-176 GROUP BIA IS :15622:2017 OUR VALUE TEST ACCORDING TO 40x40 CM (DURATECH) 12 5 0.80 36

RkJQdWJsaXNoZXIy MTQ1NTA=